Buy Original Siemens 3RH2131-1AP00-8K at Discounted Price – Shipping Worldwide

Contactor relay 3 NO + 1 NC 230 V AC 50 / 60 Hz Size S00 screw terminal

Category:

Description

product brand nameSIRIUS
product designationAuxiliary contactor
product type designation3RH2
General technical data
size of contactorS00
product extension auxiliary switchYes
insulation voltage with degree of pollution 3 at AC rated value690 V
degree of pollution3
surge voltage resistance rated value6 kV
protection class IP on the frontIP20
shock resistance at rectangular impulse
● at AC7,3g / 5 ms, 4,7g / 10 ms
shock resistance with sine pulse
● at AC11,4g / 5 ms, 7,3g / 10 ms
mechanical service life (operating cycles)
● of contactor typical30 000 000
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2K
Substance Prohibitance (Date)09/01/2022
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-5 … +60 °C
● during storage-25 … +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
no-load switching frequency
● at AC10 000 1/h
● at DC10 000 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
control supply voltage at AC
● at 50 Hz rated value230 V
● at 60 Hz rated value230 V
control supply voltage frequency
● 1 rated value50 Hz
● 2 rated value60 Hz
operating range factor control supply voltage rated value of magnet coil at AC
● at 50 Hz0.8 … 1.1
● at 60 Hz0.85 … 1.1
apparent pick-up power of magnet coil at AC37 VA
inductive power factor with closing power of the coil0.8
apparent holding power of magnet coil at AC5.7 VA
inductive power factor with the holding power of the coil0.25
closing delay
● at AC8 … 33 ms
opening delay
● at AC4 … 15 ms
arcing time10 … 15 ms
Auxiliary circuit
number of NC contacts for auxiliary contacts1
● instantaneous contact1
number of NO contacts for auxiliary contacts3
● instantaneous contact3
identification number and letter for switching elements31 E
operational current at AC-12 maximum10 A
operational current at AC-15
● at 230 V rated value10 A
● at 400 V rated value3 A
● at 500 V rated value2 A
● at 690 V rated value1 A
operational current at 1 current path at DC-12
● at 24 V rated value10 A
● at 110 V rated value3 A
● at 220 V rated value1 A
● at 440 V rated value0.3 A
● at 600 V rated value0.15 A
operational current with 2 current paths in series at DC-12
● at 24 V rated value10 A
● at 60 V rated value10 A
● at 110 V rated value4 A
● at 220 V rated value2 A
● at 440 V rated value1.3 A
● at 600 V rated value0.65 A
operational current with 3 current paths in series at DC-12
● at 24 V rated value10 A
● at 60 V rated value10 A
● at 110 V rated value10 A
● at 220 V rated value3.6 A
● at 440 V rated value2.5 A
● at 600 V rated value1.8 A
operating frequency at DC-12 maximum1 000 1/h
operational current at 1 current path at DC-13
● at 24 V rated value10 A
● at 110 V rated value1 A
● at 220 V rated value0.3 A
● at 440 V rated value0.14 A
● at 600 V rated value0.1 A
operational current with 2 current paths in series at DC-13
● at 24 V rated value10 A
● at 60 V rated value3.5 A
● at 110 V rated value1.3 A
● at 220 V rated value0.9 A
● at 440 V rated value0.2 A
● at 600 V rated value0.1 A
operational current with 3 current paths in series at DC-13
● at 24 V rated value10 A
● at 60 V rated value4.7 A
● at 110 V rated value3 A
● at 220 V rated value1.2 A
● at 440 V rated value0.5 A
● at 600 V rated value0.1 A
operating frequency at DC-13 maximum1 000 1/h
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 6 A; 0.4 kA
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection
design of the fuse link for short-circuit protection of the auxiliary switch requiredfuse gL/gG: 10 A
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm standard mounting rail
height58 mm
width45 mm
depth73 mm
required spacing
● with side-by-side mounting
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
● for grounded parts
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
● for live parts
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
type of electrical connection for auxiliary and control circuitscrew-type terminals
connectable conductor cross-section for auxiliary contacts
● solid or stranded0.5 … 4 mm²
● finely stranded with core end processing0.5 … 2.5 mm²
type of connectable conductor cross-sections
● for auxiliary contacts
— solid or stranded2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²), 2x 4 mm²
— finely stranded with core end processing2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²)
● for AWG cables for auxiliary contacts2x (20 … 16), 2x (18 … 14), 2x 12
AWG number as coded connectable conductor cross section for auxiliary contacts20 … 12
Safety related data
proportion of dangerous failures with low demand rate according to SN 3192040 %
B10 value with high demand rate according to SN 31920750 000; With 0.3 x Ie
failure rate [FIT] with low demand rate according to SN 31920100 FIT
IEC 61508
T1 value for proof test interval or service life according to IEC 6150873 a
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
.