product brand name |
SIRIUS |
product designation |
Auxiliary contactor |
product type designation |
3RH2 |
General technical data |
size of contactor |
S00 |
product extension auxiliary switch |
Yes |
insulation voltage with degree of pollution 3 at AC rated value |
690 V |
degree of pollution |
3 |
surge voltage resistance rated value |
6 kV |
protection class IP on the front |
IP20 |
shock resistance at rectangular impulse |
|
● at DC |
10g / 5 ms, 5g / 10 ms |
shock resistance with sine pulse |
|
● at DC |
15g / 5 ms, 8g / 10 ms |
mechanical service life (operating cycles) |
|
● of contactor typical |
30 000 000 |
● of the contactor with added electronically optimized auxiliary switch block typical |
5 000 000 |
● of the contactor with added auxiliary switch block typical |
10 000 000 |
reference code according to IEC 81346-2 |
K |
Substance Prohibitance (Date) |
09/01/2022 |
Ambient conditions |
installation altitude at height above sea level maximum |
2 000 m |
ambient temperature |
|
● during operation |
-5 … +60 °C |
● during storage |
-25 … +80 °C |
relative humidity minimum |
10 % |
relative humidity at 55 °C according to IEC 60068-2-30 maximum |
95 % |
Main circuit |
no-load switching frequency |
|
● at AC |
10 000 1/h |
● at DC |
10 000 1/h |
Control circuit/ Control |
type of voltage of the control supply voltage |
DC |
control supply voltage at DC rated value |
24 V |
operating range factor control supply voltage rated value of magnet coil at DC |
|
● initial value |
0.8 |
● full-scale value |
1.1 |
closing power of magnet coil at DC |
4 W |
holding power of magnet coil at DC |
4 W |
closing delay |
|
● at DC |
30 … 100 ms |
opening delay |
|
● at DC |
7 … 13 ms |
arcing time |
10 … 15 ms |
Auxiliary circuit |
number of NC contacts for auxiliary contacts |
2 |
● instantaneous contact |
2 |
number of NO contacts for auxiliary contacts |
2 |
● instantaneous contact |
2 |
identification number and letter for switching elements |
22 E |
operational current at AC-12 maximum |
10 A |
operational current at AC-15 |
|
● at 230 V rated value |
10 A |
● at 400 V rated value |
3 A |
● at 500 V rated value |
2 A |
● at 690 V rated value |
1 A |
operational current at 1 current path at DC-12 |
|
● at 24 V rated value |
10 A |
● at 110 V rated value |
3 A |
● at 220 V rated value |
1 A |
● at 440 V rated value |
0.3 A |
● at 600 V rated value |
0.15 A |
operational current with 2 current paths in series at DC-12 |
|
● at 24 V rated value |
10 A |
● at 60 V rated value |
10 A |
● at 110 V rated value |
4 A |
● at 220 V rated value |
2 A |
● at 440 V rated value |
1.3 A |
● at 600 V rated value |
0.65 A |
operational current with 3 current paths in series at DC-12 |
|
● at 24 V rated value |
10 A |
● at 60 V rated value |
10 A |
● at 110 V rated value |
10 A |
● at 220 V rated value |
3.6 A |
● at 440 V rated value |
2.5 A |
● at 600 V rated value |
1.8 A |
operating frequency at DC-12 maximum |
1 000 1/h |
operational current at 1 current path at DC-13 |
|
● at 24 V rated value |
10 A |
● at 110 V rated value |
1 A |
● at 220 V rated value |
0.3 A |
● at 440 V rated value |
0.14 A |
● at 600 V rated value |
0.1 A |
operational current with 2 current paths in series at DC-13 |
|
● at 24 V rated value |
10 A |
● at 60 V rated value |
3.5 A |
● at 110 V rated value |
1.3 A |
● at 220 V rated value |
0.9 A |
● at 440 V rated value |
0.2 A |
● at 600 V rated value |
0.1 A |
operational current with 3 current paths in series at DC-13 |
|
● at 24 V rated value |
10 A |
● at 60 V rated value |
4.7 A |
● at 110 V rated value |
3 A |
● at 220 V rated value |
1.2 A |
● at 440 V rated value |
0.5 A |
● at 600 V rated value |
0.1 A |
operating frequency at DC-13 maximum |
1 000 1/h |
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 V |
C characteristic: 6 A; 0.4 kA |
contact reliability of auxiliary contacts |
1 faulty switching per 100 million (17 V, 1 mA) |
Short-circuit protection |
design of the fuse link for short-circuit protection of the auxiliary switch required |
fuse gL/gG: 10 A |
Installation/ mounting/ dimensions |
mounting position |
+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
fastening method |
screw and snap-on mounting onto 35 mm standard mounting rail |
height |
58 mm |
width |
45 mm |
depth |
73 mm |
required spacing |
|
● with side-by-side mounting |
|
— forwards |
10 mm |
— upwards |
10 mm |
— downwards |
10 mm |
— at the side |
0 mm |
● for grounded parts |
|
— forwards |
10 mm |
— upwards |
10 mm |
— at the side |
6 mm |
— downwards |
10 mm |
● for live parts |
|
— forwards |
10 mm |
— upwards |
10 mm |
— downwards |
10 mm |
— at the side |
6 mm |
Connections/ Terminals |
type of electrical connection for auxiliary and control circuit |
screw-type terminals |
connectable conductor cross-section for auxiliary contacts |
|
● solid or stranded |
0.5 … 4 mm² |
● finely stranded with core end processing |
0.5 … 2.5 mm² |
type of connectable conductor cross-sections |
|
● for auxiliary contacts |
|
— solid or stranded |
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²), 2x 4 mm² |
— finely stranded with core end processing |
2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
● for AWG cables for auxiliary contacts |
2x (20 … 16), 2x (18 … 14), 2x 12 |
AWG number as coded connectable conductor cross section for auxiliary contacts |
20 … 12 |
Safety related data |
proportion of dangerous failures with low demand rate according to SN 31920 |
40 % |
B10 value with high demand rate according to SN 31920 |
750 000; With 0.3 x Ie |
failure rate [FIT] with low demand rate according to SN 31920 |
100 FIT |
IEC 61508 |
T1 value for proof test interval or service life according to IEC 61508 |
73 a |
Electrical Safety |
protection class IP on the front according to IEC 60529 |
IP20 |
touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front |