Buy Original Siemens 3RT10556LA008K at Discounted Price – Shipping Worldwide

Contactor, AC-3 150A 75kW/400V w/o Coil 3-pole, size S6 bar connections conventional operating mechan.Screw terminal No inbuit Auxiliary Contacts

Category:

Description

product brand nameSIRIUS
product designationPower contactor
product type designation3RT1
General technical data
size of contactorS6
product extension function module for communicationNo
power loss [W] for rated value of the current
● at AC in hot operating state27 W
● at AC in hot operating state per pole9 W
insulation voltage
● of main circuit with degree of pollution 3 rated value1 000 V
● of auxiliary circuit with degree of pollution 3 rated value500 V
surge voltage resistance
● of main circuit rated value8 kV
● of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1690 V
protection class IP
● on the frontIP00; IP20 on the front with cover / box terminal
● of the terminalIP00
shock resistance at rectangular impulse
● at AC8,5g / 5 ms, 4,2g / 10 ms
● at DC8,5g / 5 ms, 4,2g / 10 ms
shock resistance with sine pulse
● at AC13,4g / 5 ms, 6,5g / 10 ms
● at DC13,4g / 5 ms, 6,5g / 10 ms
mechanical service life (operating cycles)
● of contactor typical10 000 000
● of the contactor with added electronically optimized auxiliary switch block typical5 000 000
● of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (Date)10/01/2022
Ambient conditions
installation altitude at height above sea level maximum2 000 m
ambient temperature
● during operation-25 … +60 °C
● during storage-55 … +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
operating voltage
● at AC-3 rated value maximum1 000 V
● at AC-3e rated value maximum1 000 V
operational current
● at AC-1 at 400 V at ambient temperature 40 °C rated value185 A
● at AC-1
— up to 690 V at ambient temperature 40 °C rated value185 A
— up to 690 V at ambient temperature 60 °C rated value160 A
— up to 1000 V at ambient temperature 40 °C rated value90 A
— up to 1000 V at ambient temperature 60 °C rated value90 A
● at AC-3
— at 400 V rated value150 A
— at 500 V rated value150 A
— at 690 V rated value150 A
— at 1000 V rated value65 A
● at AC-3e
— at 400 V rated value150 A
— at 500 V rated value150 A
— at 690 V rated value150 A
— at 1000 V rated value65 A
● at AC-4 at 400 V rated value132 A
● at AC-5a up to 690 V rated value162 A
● at AC-5b up to 400 V rated value124 A
● at AC-6a
— up to 230 V for current peak value n=20 rated value150 A
— up to 400 V for current peak value n=20 rated value150 A
— up to 500 V for current peak value n=20 rated value150 A
— up to 690 V for current peak value n=20 rated value150 A
— up to 1000 V for current peak value n=20 rated value65 A
● at AC-6a
— up to 230 V for current peak value n=30 rated value105 A
— up to 400 V for current peak value n=30 rated value105 A
— up to 500 V for current peak value n=30 rated value105 A
— up to 690 V for current peak value n=30 rated value105 A
— up to 1000 V for current peak value n=30 rated value65 A
minimum cross-section in main circuit at maximum AC-1 rated value95 mm²
operational current for approx. 200000 operating cycles at AC-4
● at 400 V rated value68 A
● at 690 V rated value57 A
operational current
● at 1 current path at DC-1
— at 24 V rated value160 A
— at 110 V rated value18 A
— at 220 V rated value3.4 A
— at 440 V rated value0.8 A
— at 600 V rated value0.5 A
● with 2 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value20 A
— at 440 V rated value3.2 A
— at 600 V rated value1.6 A
● with 3 current paths in series at DC-1
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value11.5 A
— at 600 V rated value4 A
● at 1 current path at DC-3 at DC-5
— at 24 V rated value160 A
— at 220 V rated value0.6 A
— at 440 V rated value0.17 A
— at 600 V rated value0.12 A
● with 2 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value2.5 A
— at 440 V rated value0.65 A
— at 600 V rated value0.37 A
● with 3 current paths in series at DC-3 at DC-5
— at 24 V rated value160 A
— at 110 V rated value160 A
— at 220 V rated value160 A
— at 440 V rated value1.4 A
— at 600 V rated value0.75 A
operating power
● at AC-1
— at 230 V at 60 °C rated value60 kW
— at 400 V rated value105 kW
— at 400 V at 60 °C rated value105 kW
— at 690 V rated value181 kW
— at 690 V at 60 °C rated value181 kW
— at 1000 V at 60 °C rated value148 kW
● at AC-3
— at 230 V rated value45 kW
— at 400 V rated value75 kW
— at 500 V rated value90 kW
— at 690 V rated value132 kW
— at 1000 V rated value90 kW
● at AC-3e
— at 230 V rated value45 kW
— at 400 V rated value75 kW
— at 500 V rated value90 kW
— at 690 V rated value132 kW
— at 1000 V rated value90 kW
● at AC-4 at 400 V rated value75 kW
operating power for approx. 200000 operating cycles at AC-4
● at 400 V rated value38 kW
● at 690 V rated value55 kW
operating apparent power at AC-6a
● up to 230 V for current peak value n=20 rated value60 000 kVA
● up to 400 V for current peak value n=20 rated value100 000 VA
● up to 500 V for current peak value n=20 rated value130 000 VA
● up to 690 V for current peak value n=20 rated value170 000 VA
● up to 1000 V for current peak value n=20 rated value110 000 VA
operating apparent power at AC-6a
● up to 230 V for current peak value n=30 rated value40 000 VA
● up to 400 V for current peak value n=30 rated value70 000 VA
● up to 500 V for current peak value n=30 rated value90 000 VA
● up to 690 V for current peak value n=30 rated value120 000 VA
● up to 1000 V for current peak value n=30 rated value110 000 kVA
short-time withstand current in cold operating state up to 40 °C
● limited to 1 s switching at zero current maximum2 727 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 5 s switching at zero current maximum1 831 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 10 s switching at zero current maximum1 300 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 30 s switching at zero current maximum850 A; Use minimum cross-section acc. to AC-1 rated value
● limited to 60 s switching at zero current maximum703 A; Use minimum cross-section acc. to AC-1 rated value
no-load switching frequency at AC2 000 1/h
operating frequency
● at AC-1 maximum800 1/h
● at AC-2 maximum300 1/h
● at AC-3 maximum750 1/h
● at AC-3e maximum750 1/h
● at AC-4 maximum130 1/h
Control circuit/ Control
closing delay at AC20 … 95 ms
opening delay at AC40 … 60 ms
arcing time10 … 15 ms
control version of the switch operating mechanismWithout operating mechanism
Auxiliary circuit
product extension auxiliary switchNo
operational current at AC-12 maximum10 A
operational current at AC-15 at 500 V rated value2 A
UL/CSA ratings
yielded mechanical performance [hp]
● for single-phase AC motor at 230 V rated value30 hp
● for 3-phase AC motor
— at 200/208 V rated value50 hp
— at 220/230 V rated value60 hp
— at 460/480 V rated value125 hp
— at 575/600 V rated value150 hp
Short-circuit protection
design of the fuse link
● for short-circuit protection of the main circuit
— with type of coordination 1 requiredgG: 355 A (690 V, 100 kA)
— with type of assignment 2 requiredgG: 315 A (690 V, 100 kA), aM: 200 A (690 V, 50 kA), BS88: 315 A (415 V, 50 kA)
● for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionwith vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back
fastening methodscrew fixing
height172 mm
depth170 mm
required spacing
● with side-by-side mounting
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
● for grounded parts
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
● for live parts
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
type of electrical connection
● for main current circuitConnection bar
● for auxiliary and control circuitscrew-type terminals
● at contactor for auxiliary contactsScrew-type terminals
● of magnet coilScrew-type terminals
width of connection bar17 mm
thickness of connection bar3 mm
diameter of holes9 mm
number of holes1
type of connectable conductor cross-sections for AWG cables for main contacts4 … 250 kcmil
connectable conductor cross-section for main contacts
● solid or stranded25 … 120 mm²
● stranded25 … 120 mm²
Safety related data
product function
● mirror contact according to IEC 60947-4-1Yes
● positively driven operation according to IEC 60947-5-1No
suitability for use safety-related switching OFFNo
B10 value with high demand rate according to SN 319201 000 000
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front with box terminal/cover
.